Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
China Journal of Chinese Materia Medica ; (24): 2074-2080, 2018.
Article in Chinese | WPRIM | ID: wpr-690529

ABSTRACT

In this work, two algorithms (overlapping method and the probability-based method) for design space calculation were compared by using the data collected from extraction process of Codonopsis Radix as an example. In the probability-based method, experimental error was simulated to calculate the probability of reaching the standard. The effects of several parameters on the calculated design space were studied, including simulation number, step length, and the acceptable probability threshold. For the extraction process of Codonopsis Radix, 10 000 times of simulation and 0.02 for the calculation step length can lead to a satisfactory design space. In general, the overlapping method is easy to understand, and can be realized by several kinds of commercial software without coding programs, but the reliability of the process evaluation indexes when operating in the design space is not indicated. Probability-based method is complex in calculation, but can provide the reliability to ensure that the process indexes can reach the standard within the acceptable probability threshold. In addition, there is no probability mutation in the edge of design space by probability-based method. Therefore, probability-based method is recommended for design space calculation.

2.
Journal of the Korean Ophthalmological Society ; : 1315-1320, 2013.
Article in Korean | WPRIM | ID: wpr-93351

ABSTRACT

PURPOSE: To report the results of surgical repairing of inferomedial orbital wall fractures accompanied with loss of bony strut by an overlapping method using Resorb X(R) plates (poly(D,L)-lactic acid). METHODS: To repair inferomedial orbital wall fractures with loss of bony strut, we bent the medial aspect of the plate for floor fracture according to the anatomical structure and then inserted the floor implant, which was supported by anterior, posterior and lateral margins of the floor fracture. Then, the medial implant, which was supported by the bent medial edge of the floor implant, was inserted. Postoperatively, we analyzed the outcomes of 21 patients regarding postoperative enophthalmos, limitation of eye movement (LOM) and diplopia. The diagonal lengths of the orbit in the operated side were compared with the non-traumatized side based on the coronal view of the postoperative CT scans to determine the success or failure of the reconstruction. RESULTS: The average postoperative enophthalmic value was 0.5 mm, and no significant differences between the orbital diagonal lengths of the operated and non-operated eyes were observed. The LOM shown in 7 out of 8 patients was completely resolved during the postoperative follow-up period. All patients with diplopia, including one patient who showed partial remission of LOM, experienced complete symptom resolution. No other complications related to the implant were recorded. CONCLUSIONS: Inferomedial orbital wall fractures with the loss of bony strut can be successfully repaired by the overlapping method using Resorb X(R) implants.


Subject(s)
Humans , Diplopia , Enophthalmos , Eye , Eye Movements , Floors and Floorcoverings , Follow-Up Studies , Orbit , Orbital Implants
SELECTION OF CITATIONS
SEARCH DETAIL